LC_XG400L Basic Serial Command Functional Specifications
9/24
6.4 Operation Requirements
In the following status of projector, Available Functional Execution Commands are limited.
Projector Status Available Functional Execution Commands
Standby Mode C00: POWER ON
Countdown in process
C00: POWER ON Countdown is terminated
C01: POWER OFF
C02: POWER OFF Countdown is terminated
C46: ZOOM -
C47: ZOOM +
C4A: FOCUS -
C4B: FOCUS +
C5D: LENS SHIFT UP
C5E: LENS SHIFT DOWN
C5F:LENS SHIFT LEFT
C60:LENS SHIFT RIGHT
When ZOOM+/-, FOCUS +/-, LENS SHIFTUP/
DOWN/LEFT/RIGHT are executed during Countdown
is in process, POINTER UP/DOWN(C3C/C3D)
become effective, and ZOOM/FOCUS/LENS SHIFT
become enable to control by POINTER UP/DOWN.
Cooling Down in process NONE (No Execution)
Cooling Down due to Abnormal
Temperature
NONE (No Execution)
Abnormal Temperature Status NONE (No Execution)
Abnormal Power Status NONE (No Execution)
Power-Save Cooling Down in process NONE (No Execution)
Power Save Status
C00: POWER ON
C01: POWER OFF
Cooling Down in process after OFF
operation due to Lamp Failure
NONE (No Execution)
Note) in above status, the projector returns [ACK] [CR] even if it receives the other command.