LC-X7 Basic Serial Command Functional Specifications
21/24
7.10 Status 2 Read Command
COMMAND “CRA” [CR]
Detail Get the operating status of Video mute.
Acceptable “%1” [CR]
%
Return a hex digit of 1 byte as two columns of character string.
Define each bit as eight bits by a hex digit as follows.
**** ****
|||| ||| bit0:Shutter Close = 1 / Open = 0
|||| ||└― bit1:Spare
|||| └―― bit2:Spare
|||| └――― bit3:Spare
|||└――――― bit4:Spare
||└―――――― bit5:Spare
└――――――― bit6:Spare
└――――――――bit7:No signal=1, signal=0
ex:
Normal Operation: “00”
Shutter Close: “01”
No signal: “80”
When it is in Standby mode or Cooling Down process, it returns
“FF” even if the status is above.
Response
Unacceptable “?” [CR]