LC_X80 Basic Serial Command Functional Specifications
17/23
6.52 LENS SHIFT DOWN Command
Command
“C5E” [CR]
Detail Move projection area downward.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.53 LENS SHIFT LEFT Command
Command
“C5F” [CR]
Detail Move projection area leftward.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.54 LENS SHIFT RIGHT Command
Command
“C60” [CR]
Detail Move projection area rightward.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.55 AUTO PC ADJ. Command
Command
“C89” [CR]
Detail
Execute AUTO PC ADJ. function
This command works the same way as “AUTO PC ADJ.” button of the remote
control.
Sending this command during Auto PC Adj. process terminates the operation.
This is the same by “AUTO PC” button of the remote control.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.56 PRESENTATION TIMER Command
Command
“C8A” [CR]
Detail
Start Timer for presentation
This command works the same way as “P-TIMER” button of the
remote control.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.57 KEYSTONE ↑ Command
Command
“C8E” [CR]
Detail
Correct keystone distortion by reducing upper part of image. This command
invokes both operations of keystone distortion correction and OSD display,
regardless of whether the “KEYSTONE” OSD has been already displayed or not.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]